VAT

ADV CONTROL 8-32A 110-240V

Product Code: LUCB32FU

Price
£146.00 ex. VAT £175.20 inc. VAT

Add To Wishlist
Control unit, TeSys U, 8-32A, 3P motor protection & diagnostic, class 10, coil 110-240V AC/DC

Product Details

TeSys U control and diagnostic unit to be inserted in advanced power bases LUB320, LUB380, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 15kW@400V. It provides full protection to motors with a rated current Ir 8-32A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). It provides a thermal overload alarm to be used locally using a LUFDA module or remotely using a LULC module, and a test push button for overload simulation. To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Available In 3-7 Days

ENVPEP080204EN_V1
Short-circuit Release Function Undelayed
Type Of Motor Protection Electronic Release
Voltage Type For Actuating AC/DC / AC/DC
Degree Of Protection (IP Rating) IP20
Depth 126
Height 154
Width 45
Number Of Auxiliary Contacts As Normally Closed Contact 1
Number Of Auxiliary Contacts As Normally Open Contact 1
Rated Control Supply Voltage At DC 24
Rated Operation Power At AC-3, 400 V 15
Type Of Electrical Connection Of Main Circuit Screw Connection
Rail Mounting Possible Yes
Supporting Protocol For AS-Interface Safety At Work No
Supporting Protocol For ASI No
Supporting Protocol For CAN No
Supporting Protocol For Data-Highway No
Supporting Protocol For DeviceNet No
Supporting Protocol For DeviceNet Safety No
Supporting Protocol For EtherNet/IP No
Supporting Protocol For Foundation Fieldbus No
Supporting Protocol For INTERBUS No
Supporting Protocol For INTERBUS-Safety No
Supporting Protocol For LON No
Supporting Protocol For MODBUS No
Supporting Protocol For Other Bus Systems No
Supporting Protocol For PROFIBUS No
Supporting Protocol For PROFINET CBA No
Supporting Protocol For PROFINET IO No
Supporting Protocol For PROFIsafe No
Supporting Protocol For SafetyBUS P No
Supporting Protocol For SERCOS No
Supporting Protocol For SUCONET No
Supporting Protocol For TCP/IP No
Number Of Command Positions 3
Rated Control Supply Voltage At AC 50 Hz 24
Rated Control Supply Voltage At AC 60 Hz 24
Ambient Temperature, Upper Operating Limit 70
Coordination Class According To IEC 60947-4-3 Class 2
External Reset Possible No
Kind Of Motor Starter Direct Starter
Number Of Indicator Lights 0
Rated Conditional Short-circuit Current, Type 1, 480 Y/277 V 10000
Rated Conditional Short-circuit Current, Type 1, 600 Y/347 V 4000
Rated Conditional Short-circuit Current, Type 2, 230 V 50000
Rated Conditional Short-circuit Current, Type 2, 400 V 50000
Rated Operation Current Ie 32
Rated Operation Current At AC-3, 400 V 32
Rated Operation Power At AC-3, 230 V, 3-phase 7.5
Rated Power, 460 V, 60 Hz, 3-phase 15
Rated Power, 575 V, 60 Hz, 3-phase 15
Suitable For Emergency Stop No
Type Of Electrical Connection For Auxiliary- And Control Current Circuit Screw Connection
With Fuse No
With Short-circuit Release Yes
With Transformer No